1

Bodine B94GU Emergency Ballast

Bodine B94GU B94CGU

Bodine B94GU Emergency Ballast. The B94GU emergency ballast works in conjunction with an AC ballast to convert new or existing fluorescent fixtures into emergency lighting. The
emergency ballast consists of a high-temperature nickel-cadmium battery, charger and electronic circuitry in one compact case. Universal input voltage; One-lamp emergency illumination for 4-pin fluorescent lamps (without integral starter); Suitable for low mercury lamps.

UL Listed for US and Canada
Factory or Field Installation
(Indoor and Damp)

Illumination Time
90 Minutes

Initial Light Output
300 – 750 Lumens

Full Warranty
2 Years (NOT pro-rata)

Universal Input Voltage
120 Through 277 VAC, 50 or 60 Hz

AC Input Current
50 mA

AC Input Power Rating
4.0 Watts

Test Switch
Single Pole

Battery
High-Temperature, Maintenance-Free
Nickel-Cadmium Battery
7- to 10-Year Life Expectancy

Battery Charging Current
300 mA

Recharge Time
24 Hour

Charging Indicator Light
LED

Temperature Rating (Ambient)
0°C to + 50°C (32°F to 122°F)

Dimensions
9.4″ x 2.4″ x 1.5″
(238 mm x 60 mm x 38 mm)
Mounting Center 8.9″ (226 mm)

Weight
3 lbs. (1.4 kg)

Model B94GU is warranted for two (2) full years from date of purchase. Please see detailed warranty information on the Signify official website.

For other items like the Bodine B94GU Emergency Ballast click here.

For more information on Bodine’s line of lighting solutions click here.




Bodine BDL60U Emergency Ballast

Bodine BDL60U

Bodine BDL60U Emergency Ballast / Emergency battery backup. Suitable for damp locations and suitable for use with most 32W – 215W (4’ – 8’) T8, T10 or T12 fluorescent lamps without integral starters, including U-shaped, HO, VHO, circline and energy-saving.

One- or two-lamp emergency; universal input voltage: 120 through 277 VAC, 50 or 60 Hz
Replaces model B60U

UL Listed
Factory or Field Installation
(Indoor and Damp)

Illumination Time
90 Minutes

Initial Light Output
300 – 700 Lumens

Full Warranty
3 Years (NOT pro-rata)

Universal Input Voltage
120 Through 277 VAC, 50 or 60 Hz

AC Input Current
60 mA

AC Input Power Rating
5.0 Watts

Test Switch
Single Pole

Battery
High-Temperature, Maintenance-Free
Nickel-Cadmium Battery
7- to 10-Year Life Expectancy

Battery Charging Current
280 mA
Recharge Time
24 Hour

Charging Indicator Light
LED

Temperature Rating (Ambient)
0°C to +50°C (32°F to 122°F)

Dimensions
9.4″ x 2.4″ x 1.5″
(238 mm x 60 mm x 38 mm)
Mounting Center 8.9″ (226 mm)

Weight
2.5 lbs. (1.13 kg)

Further specifications on the Bodine BDL60U Emergency Ballast click here, or visit the Signify official website.

Model BDL60U is warranted for three (3) full years from date of purchase. Please see detailed warranty information on the Signify official web site.




Bodine BLCD-20B Generator Device

Bodine BLCD-20B Generator Device. Emergency Lighting Control Unit. Supports lighting load up to 20A. For Generator or Central Inverter Supplied Generator; 120 or 277 VAC, 50/60 Hz; Auto Select.

Benefits

• Allows generator supplied emergency lighting regardless of wall switch position
• Energy cost savings benefits by elimating constant night lighting
• Compatible with LED and fluorescent loads up to 20A
and incandescent loads up to 10A.
• Small size – Can be mounted onto a junction box
• Designed with Auto Select to detect proper input voltage
• Plenum Rated (UL 2043)
• Interfaces with fire alarm panel or security system

Specifications

UL Listed for US and Canada
UL924 Emergency Lighting Compliant
Field Installation
(Indoor and Damp)

Full Warranty
3 Years (NOT pro-rata)

Input Voltage
120/277 VAC, 50/60 Hz

Output Voltage
120/277 VAC, (Auto Select) 50/60 Hz
Lighting Load Rating

Maximum Load:
Ballast – 20A @ 120/277VAC
LED Driver – 20A @ 120/277VAC
Incandescent – 10A @ 120VAC

Temperature Rating (Ambient)
0°C to +50°C (+32°F to +122°F)

Relative Humidity Range
5 to 95%, noncondensing

Housing
Fire rated UL94 V-0, 176°F (80°C)

Plenum Rating
UL 2043 Plenum Rated

Dimensions
2.97”x 1.64”x 1.7” with a 1/2” threaded nipple
(76 mm x 42 mm x 43 mm)
Weight
6.4 oz. (0.18 kg)

For other items like the Bodine BLCD-20B Generator Device click here.

For more information on Bodine’s line of lighting solutions click here.

 




Bodine BLCD16DIM Generator Device

Bodine BLCD16DIM Generator Device. Emergency lighting control unit 0-10 Vdc dimmer override. Supports lighting load up to 16A. The BLCD16DIM works in conjunction with an
auxiliary generator or central inverter system. The unit is designed to control lighting in areas where emergency lighting fixtures are connected on dedicated emergency lighting circuits that are typically on 24 hours per day.

Benefits

• Allows generator supplied emergency lighting regardless of wall switch position
• Energy cost savings benefits by elimating constant night lighting
• LED rating – Up to 16 Amp electronic ballast rating
• Small size – Can be mounted onto a junction box
• 0-10 Vdc dimmer override
• Plenum Rated (UL 2043)
• Interfaces with fire alarm panel or security system

Specifications

UL Listed for US and Canada
UL924 Emergency Lighting Compliant
Field Installation (Indoor and Damp)

Full Warranty
5 Years

Input Voltage
120/277 VAC, 50/60 Hz

LED Lighting Load Rating
Up to 16A electronic ballast rating

Temperature Rating (Ambient)
-35°C to +60°C (-30°F to +140°F)

Relative Humidity Range
5 to 95%, (noncondensing)

Housing
UL accepted for use in Plenum, NEMA 1

Wire
16” 600V Rated

Dimensions
4.0”x 4.0”x 1.81” with a 1/2” threaded nipple
(101.6 mm x 101.6 mm x 45.97 mm)
Weight
0.675 lbs.

For other items like the Bodine BLCD16DIM Generator Device click here.

For more information on Bodine’s line of lighting solutions click here.




Bodine ELI-S-10 Emergency Lighting Inverter

Bodine ELI-S-10 Emergency Lighting Inverter. 10VA Pure Sine Wave Output Nano Inverter Automatic Output Voltage Select. Patented automatic dimming (0-10V) of connected loads.

Benefits

• Constant 10VA output power
• Automatic output voltage select
• Works with LED and fluorescent luminaires
• Compatible with Type B TLED and screw based lamps (up to 10VA)
• Ideally compatible with single and multi-channel LED dimming drivers
• Complies with Part 15 of the FCC (Federal Communications Commission) Rules
• Meets California Energy Commission Title 20 efficiency requirements
• Remote-mounting up to 250 feet maximum

Specifications

UL Listed for US and Canada
Listed to UL924 and tested to CSA 22.2, No. 141
For Field or Factory Installation (Indoor and Damp)

Maximum Output Power
10VA into load
Total Connected Output Load,

Dimmable lighting loads
Input power 50W maximum with most

LED drivers and fluorescent ballasts
(consult factory for driver compatibility)

Non-dimmable lighting loads
Input power 10VA maximum

Illumination Time
90 Minutes

AC Input Voltage and Current (charging only)
120 through 277VAC, 50/60 Hz, 80 mA

Recharge Time
24 Hours

Charging Indicator Light / Test Switch
Integrated LED Test Switch

Battery
Maintenance-Free Li-ion Battery

Output Voltage, Automatically Selected
120 VAC +/- 10%, or 277 VAC +/- 10%

Output Frequency
60 Hz, ± 5%

Transfer Time
2 to 5 seconds

Temperature Rating (Ambient)
32° F to 122° F (0° C to 50° C)

Dimensions
15.34″ L x 2.25″ W x 1.16″ H
(390mm x 58mm x 30mm)
Mount center – 15.0″ (381mm)
Weight
3.45 lbs. (1.56kg)

Warranty
5 years (NOT pro-rata)

For other items like the Bodine ELI-S-10 Emergency Lighting Inverter click here.

For more information on Bodine’s line of lighting solutions click here.




Bodine ELI-S-10-CEC Emergency Lighting Inverter

Bodine ELI-S-10-CEC Emergency Lighting Inverter. 10VA Pure Sine Wave Output Nano Inverter Automatic Output Voltage Select Regulates AC Dimming Drivers to 10VA.




Bodine ELI-S-100-CEC Emergency Lighting Inverter

Bodine ELI-S-100-CEC Emergency Lighting Inverter. Sinusoidal (Sine Wave) Output 100 VA Maximum Output Power Automatic Output Voltage Select Automatic Dimming (0 to 10V) of Connected Load.

Benefits

• Automatic output voltage select
• Automatic dimming (0 to 10V) of connected load
• Adjustable maximum dim setting
• Works with LED and fluorescent fixtures
• Ideal for (but not limited to) screw-base LED lamps
• Compatible with AC (line voltage) driven TLED lamps
• Remote-mounting up to 250 feet maximum
• Meets CEC Title 20 efficiency standards

Specifications

UL Listed for US and Canada
Listed to UL924 and tested to CSA 22.2 No. 141
Field or Factory Installation (Indoor and Damp)
Output Class 2 Compliant

Maximum Connected Load Power
400 W*

Warranty
5 Years Full Coverage (not including battery)
3 Year Battery warranty, plus 7 years
additional pro-rating

Illumination Time
90 Minutes

AC Input Voltage
120 VAC, 60 Hz or 277 VAC, 60 Hz

Input Charging Current
370 mA Max Charging

Output Voltage
120 or 277 VAC, 60Hz, automatically selected

Output Power
Maximum output: 100VA
Minimum load P.F +/- 0.75

Transfer Time
2 – 5 seconds

Charging Indicator Light/Test Switch
Integrated LED/test switch

Battery
Maintenance-Free Sealed Lead Acid Battery

Recharge Time
24 Hours

Temperature Rating (Ambient)
32° F to 104° F (0° C to 40° C)

Dimensions
12.56” x 9.81” x 4.68”
(319 mm x 249 mm x 119 mm)
Weight
25 lbs. With Batteries installed

For other items like the Bodine ELI-S-100-CEC Emergency Lighting Inverter click here.

For more information on Bodine’s line of lighting solutions click here.




Bodine ELI-S-10CDF-CEC Emergency Lighting Inverter

Bodine ELI-S-10CDF-CEC Emergency Lighting Inverter. This model includes separate 2W-ITS with conduit and 90? adapter. 10VA Pure Sine Wave Output Nano Inverter Automatic Output Voltage Select Regulates AC Dimming Drivers to 10VA.




Bodine ELI-S-20 Emergency Lighting Inverter

Bodine ELI-S-20 Emergency Lighting Inverter. Sinusoidal (Sine Wave) Output 20 or 25 Watts Power Auto Select 120 or 277 VAC Code-Compliant 90-Minute Runtime.

Benefits

Sine wave output
• Fused output load connections
• Works with LED and fluorescent fixtures
• Ideal for (but not limited to) screw-base LED lamps
• Auto Select feature helps reduce wiring errors
• Compatible with AC (line voltage) driven TLED lamps
• Remote-mounting up to 250 feet maximum

Specifications

UL Listed for US and Canada
Listed to UL924 and tested to CSA 22.2 No. 141
Field or Factory Installation (Indoor and Damp)Output Class 2 Compliant

Illumination Time
90 Minutes

Maximum Load Power (including AC ballast/driver)
20 W (0°C to 50°C) UL and CSA
25 W (0°C to 45°C) UL only

Full Warranty
5 years (NOT pro-rata)

AC Input Voltage
120 or 277 VAC, 60 Hz

AC Input Current
65 mA

AC Input Power Rating
8.0 W

Output Voltage
120/277 VAC (Auto Select), 60Hz

Output Current
120 V, 165 or 210 mA 277 V, 72 or 90 mA

Transfer Time
2 to 5 seconds

Test Switch
Single Pole (Momentary)

Battery
High-Temperature, Maintenance-Free ,
Nickel-Cadmium Battery,
7- to 10-year life expectancy

Battery Charging Current
250 mA

Recharge Time
24 Hours

Charging Indicator Light
LED

Temperature Rating (Ambient)
32° F to 122° F (0° C to 50° C) for 20 W
32° F to 113° F (0° C to 45° C) for 25 W
Weight
5 lbs. (2.3 kg)

For other items like the Bodine ELI-S-20 Emergency Lighting Inverter click here.

For more information on Bodine’s line of lighting solutions click here.




Bodine ELI-S-250 Emergency Lighting Inverter

Bodine ELI-S-250 Emergency Lighting Inverter. Sinusoidal (Sine Wave) Output. 250 Watts Power Maximum. Automatic Output Voltage Select. Automatic Dimming (0 to 10V) of connected Load.

Benefits

• Automatic output voltage select
• Automatic dimming (0 to 10V) of connected load
• Removable/Replaceable electronics module
• Works with LED and fluorescent fixtures
• Ideal for (but not limited to) screw-base LED lamps
• Compatible with AC (line voltage) driven TLED lamps
• Remote-mounting up to 1,000 feet maximum

Specifications

UL Listed for US and Canada
Listed to UL924 and tested to CSA 22.2, No. 141
For Field Installation (Indoor and Damp)

Maximum Output Power
250 W into load PF +/- 0.90 (280 VA)

Maximum Connected Load Power
800 W*

Illumination Time
90 Minutes

AC Input Voltage
120 VAC, 60 Hz or 277 VAC, 60 Hz

AC Input Current, (battery charging)
1000 mA Max, 120Vac or
360 mA Max, 277Vac,

Battery: 2 ea. required
12V (nominal), 35Ah
Maintenance-Free Sealed Lead Acid Battery

Recharge Time
24 Hours
Charging Indicator Light / Test Switch
Integrated LED Test Switch

Output Voltage, Automatically Selected
120 VAC +/- 10%, or 277 VAC +/- 10%

Output Frequency
60 Hz, ± 5%

Transfer Time
2 to 5 seconds

Temperature Rating (Ambient)
68° F to 86° F (20° C to 30° C)

Dimensions
12.0″ H x 12.5″ W x 10.0″ D
(317mm x 305mm x 254mm)

Weight
Enclosure and Electronics only: 16 lbs. (7.26 Kg)
Batteries, 25 lbs. ea., Batteries total: 50 lbs. (22.6 Kg)

Warranty
5 Years (not including batteries)
3 Year Battery warranty, plus 7 years additional
pro-rating

For other items like the Bodine ELI-S-250 Emergency Lighting Inverter click here.

For more information on Bodine’s line of lighting solutions click here.




Bodine GTD Emergency Lighting Control Generator Device

Bodine GTD Emergency Lighting Control Generator Device. Emergency Lighting Control Device for generator or central inverter supplied lighting. The GTD emergency lighting control device works in conjunction with an auxiliary generator or a central inverter system to power existing fluorescent or LED fixtures for egress lighting regardless of fixture wall switch position. The device consists of relay switching circuitry and
fusing in one compact galvanized steel case. One emergency lighting control device per fixture is used to bypass the fixture wall switch, allowing the building’s generator (or central inverter) to bring on switchable fixtures.

Benefits

• Allows generator supplied emergency lighting regardless of wall switch position
• Energy cost savings benefits by elimating constant night lighting
• Can be used with fluorescent or LED lighting loads
• Suitable for indoor or damp locations

Specifications

UL Listed
UL924 Emergency Lighting Compliant
Factory or Field Installation

Full Warranty
5 Years (NOT pro-rata)

Dual Input Voltage
120/277 VAC, 60 Hz

AC Input Current
280 mA

AC Input Power Rating
1.6 Watts

Fusing
All inputs fused to 3 A Maximum

Temperature Rating (Ambient)
-20°C to +65°C (-4°F to 149°F)

Dimensions
8” x 1.18” x 1.18” (204 mm x 30 mm x 30 mm)
Mounting Center 7.60” (193 mm)
Weight
0.50 lbs. (0.23 kg)

For other items like the Bodine GTD Emergency Lighting Control Generator Device click here.

For more information on Bodine’s line of lighting solutions click here.




Bodine GTD10DIM Generator Device

Bodine GTD10DIM Generator Device. Switch Bypass Device (Automatic Load Control Relay) 0-10 VDC dimmer override.
Up to 10A electronic ballast/driver rating. The GTD10DIM emergency lighting control device works in conjunction with an auxiliary generator or a central inverter system to power existing fluorescent or LED fixtures for egress lighting regardless of fixture wall switch position. The device consists of
relay switching circuitry and fusing in one compact case. The GTD10DIM bypasses the fixture wall switch, allowing the building’s generator (or central inverter) to bring on switchable fixtures.

Benefits

• Allows ON/OFF switching of generator supplied emergency lighting
• Energy cost savings benefits by eliminating constant night lighting
• LED rating – Up to 10A electronic ballast rating
• 0-10 VDC dimmer override

Specifications

UL LISTED for US and Canada
UL924 Emergency Lighting Compliant
Field Installation (Indoor and Damp)

Full Warranty
5 Years

Input Voltage
120 Through 277 VAC, 50/60 Hz

LED Lighting Load Rating
Up to 10A electronic ballast rating

Temperature Rating (Ambient)
-35 to 60 C (-30 to 140 F)

Relative Humidity Range
5 to 95%, (noncondensing)

Housing
UL accepted for use in Plenum, NEMA 1

Wire
16” 600V rated

Dimensions
4.5” x 1.675” x 1.32”
(114.3 mm x 42.5 mm x 33.5 mm)
Weight
0.43 lbs.

Application

 

For other items like the Bodine GTD10DIM Generator Device click here.

For more information on Bodine’s line of lighting solutions click here.