Bodine ELI-S-10-CEC Emergency Lighting Inverter

Bodine ELI-S-10-CEC Emergency Lighting Inverter. 10VA Pure Sine Wave Output Nano Inverter Automatic Output Voltage Select Regulates AC Dimming Drivers to 10VA.
1
Bodine ELI-S-10-CEC Emergency Lighting Inverter. 10VA Pure Sine Wave Output Nano Inverter Automatic Output Voltage Select Regulates AC Dimming Drivers to 10VA.
Bodine ELI-S-100-CEC Emergency Lighting Inverter. Sinusoidal (Sine Wave) Output 100 VA Maximum Output Power Automatic Output Voltage Select Automatic Dimming (0 to 10V) of Connected Load.
Benefits
• Automatic output voltage select
• Automatic dimming (0 to 10V) of connected load
• Adjustable maximum dim setting
• Works with LED and fluorescent fixtures
• Ideal for (but not limited to) screw-base LED lamps
• Compatible with AC (line voltage) driven TLED lamps
• Remote-mounting up to 250 feet maximum
• Meets CEC Title 20 efficiency standards
Specifications
UL Listed for US and Canada
Listed to UL924 and tested to CSA 22.2 No. 141
Field or Factory Installation (Indoor and Damp)
Output Class 2 Compliant
Maximum Connected Load Power
400 W*
Warranty
5 Years Full Coverage (not including battery)
3 Year Battery warranty, plus 7 years
additional pro-rating
Illumination Time
90 Minutes
AC Input Voltage
120 VAC, 60 Hz or 277 VAC, 60 Hz
Input Charging Current
370 mA Max Charging
Output Voltage
120 or 277 VAC, 60Hz, automatically selected
Output Power
Maximum output: 100VA
Minimum load P.F +/- 0.75
Transfer Time
2 – 5 seconds
Charging Indicator Light/Test Switch
Integrated LED/test switch
Battery
Maintenance-Free Sealed Lead Acid Battery
Recharge Time
24 Hours
Temperature Rating (Ambient)
32° F to 104° F (0° C to 40° C)
Dimensions
12.56” x 9.81” x 4.68”
(319 mm x 249 mm x 119 mm)
Weight
25 lbs. With Batteries installed
For other items like the Bodine ELI-S-100-CEC Emergency Lighting Inverter click here.
For more information on Bodine’s line of lighting solutions click here.
Bodine ELI-S-10CDF-CEC Emergency Lighting Inverter. This model includes separate 2W-ITS with conduit and 90? adapter. 10VA Pure Sine Wave Output Nano Inverter Automatic Output Voltage Select Regulates AC Dimming Drivers to 10VA.
Bodine ELI-S-20 Emergency Lighting Inverter. Sinusoidal (Sine Wave) Output 20 or 25 Watts Power Auto Select 120 or 277 VAC Code-Compliant 90-Minute Runtime.
Benefits
Sine wave output
• Fused output load connections
• Works with LED and fluorescent fixtures
• Ideal for (but not limited to) screw-base LED lamps
• Auto Select feature helps reduce wiring errors
• Compatible with AC (line voltage) driven TLED lamps
• Remote-mounting up to 250 feet maximum
Specifications
UL Listed for US and Canada
Listed to UL924 and tested to CSA 22.2 No. 141
Field or Factory Installation (Indoor and Damp)Output Class 2 Compliant
Illumination Time
90 Minutes
Maximum Load Power (including AC ballast/driver)
20 W (0°C to 50°C) UL and CSA
25 W (0°C to 45°C) UL only
Full Warranty
5 years (NOT pro-rata)
AC Input Voltage
120 or 277 VAC, 60 Hz
AC Input Current
65 mA
AC Input Power Rating
8.0 W
Output Voltage
120/277 VAC (Auto Select), 60Hz
Output Current
120 V, 165 or 210 mA 277 V, 72 or 90 mA
Transfer Time
2 to 5 seconds
Test Switch
Single Pole (Momentary)
Battery
High-Temperature, Maintenance-Free ,
Nickel-Cadmium Battery,
7- to 10-year life expectancy
Battery Charging Current
250 mA
Recharge Time
24 Hours
Charging Indicator Light
LED
Temperature Rating (Ambient)
32° F to 122° F (0° C to 50° C) for 20 W
32° F to 113° F (0° C to 45° C) for 25 W
Weight
5 lbs. (2.3 kg)
For other items like the Bodine ELI-S-20 Emergency Lighting Inverter click here.
For more information on Bodine’s line of lighting solutions click here.
Bodine ELI-S-250 Emergency Lighting Inverter. Sinusoidal (Sine Wave) Output. 250 Watts Power Maximum. Automatic Output Voltage Select. Automatic Dimming (0 to 10V) of connected Load.
Benefits
• Automatic output voltage select
• Automatic dimming (0 to 10V) of connected load
• Removable/Replaceable electronics module
• Works with LED and fluorescent fixtures
• Ideal for (but not limited to) screw-base LED lamps
• Compatible with AC (line voltage) driven TLED lamps
• Remote-mounting up to 1,000 feet maximum
Specifications
UL Listed for US and Canada
Listed to UL924 and tested to CSA 22.2, No. 141
For Field Installation (Indoor and Damp)
Maximum Output Power
250 W into load PF +/- 0.90 (280 VA)
Maximum Connected Load Power
800 W*
Illumination Time
90 Minutes
AC Input Voltage
120 VAC, 60 Hz or 277 VAC, 60 Hz
AC Input Current, (battery charging)
1000 mA Max, 120Vac or
360 mA Max, 277Vac,
Battery: 2 ea. required
12V (nominal), 35Ah
Maintenance-Free Sealed Lead Acid Battery
Recharge Time
24 Hours
Charging Indicator Light / Test Switch
Integrated LED Test Switch
Output Voltage, Automatically Selected
120 VAC +/- 10%, or 277 VAC +/- 10%
Output Frequency
60 Hz, ± 5%
Transfer Time
2 to 5 seconds
Temperature Rating (Ambient)
68° F to 86° F (20° C to 30° C)
Dimensions
12.0″ H x 12.5″ W x 10.0″ D
(317mm x 305mm x 254mm)
Weight
Enclosure and Electronics only: 16 lbs. (7.26 Kg)
Batteries, 25 lbs. ea., Batteries total: 50 lbs. (22.6 Kg)
Warranty
5 Years (not including batteries)
3 Year Battery warranty, plus 7 years additional
pro-rating
For other items like the Bodine ELI-S-250 Emergency Lighting Inverter click here.
For more information on Bodine’s line of lighting solutions click here.
Bodine ELI-S-400 Emergency Lighting Inverter. Emergency Lighting Inverter. Sinusoidal (Sine Wave) Output. 400 VA Power Maximum.
Benefits
• Sine wave output
• 400 VA power maximum
• Transfer Time: 50 ms
Specifications
ETL Listed
Listed to UL924
For Field Installation
Illumination Time
90 Minutes
Maximum Load Power
400VA
Full Warranty
1 year full, 4 years pro-rata
Input
• Input voltage (dual): 120 or 277VAC
• Input frequency: 60 Hz
• Synchronizing slew rate: 1 Hz per second nominal
• Input surge protection: Meets UL 924
Output
• Output voltage (dual): 120 or 277VAC, 60Hz
• Output regulation: (static) ± 5% based on a
0 – 100% resistive load
• Output distortion: Less than 3% THD linear load
• Load Power Factor: .5 lag to .5 lead
• Output frequency: Normally, Synchronized to utility,
± 2 Hz during emergency
• Overload: 150% for five seconds
• Time to transfer to inverter after a utility
power failure: 50 ms.
Charging Indicator Light/Test Switch
Integrated LED/test switch
Battery Type
Maintenance-Free Sealed Lead Calcium
Recharge Time
Less than 168 Hours (meets UL924)
Battery Protection
Automatic low-battery voltage disconnect and reverse polarity
protection. Automatic restart upon utility return
Temperature Rating
68°F to 86°F (20°C to 30°C)
Dimensions
18″W x 8″D x 15″H
Weight
98 lbs (44.4 kg)
For other items like the Bodine ELI-S-400 Emergency Lighting Inverter click here.
For more information on Bodine’s line of lighting solutions click here.
Bodine GTD Emergency Lighting Control Generator Device. Emergency Lighting Control Device for generator or central inverter supplied lighting. The GTD emergency lighting control device works in conjunction with an auxiliary generator or a central inverter system to power existing fluorescent or LED fixtures for egress lighting regardless of fixture wall switch position. The device consists of relay switching circuitry and
fusing in one compact galvanized steel case. One emergency lighting control device per fixture is used to bypass the fixture wall switch, allowing the building’s generator (or central inverter) to bring on switchable fixtures.
Benefits
• Allows generator supplied emergency lighting regardless of wall switch position
• Energy cost savings benefits by elimating constant night lighting
• Can be used with fluorescent or LED lighting loads
• Suitable for indoor or damp locations
Specifications
UL Listed
UL924 Emergency Lighting Compliant
Factory or Field Installation
Full Warranty
5 Years (NOT pro-rata)
Dual Input Voltage
120/277 VAC, 60 Hz
AC Input Current
280 mA
AC Input Power Rating
1.6 Watts
Fusing
All inputs fused to 3 A Maximum
Temperature Rating (Ambient)
-20°C to +65°C (-4°F to 149°F)
Dimensions
8” x 1.18” x 1.18” (204 mm x 30 mm x 30 mm)
Mounting Center 7.60” (193 mm)
Weight
0.50 lbs. (0.23 kg)
For other items like the Bodine GTD Emergency Lighting Control Generator Device click here.
For more information on Bodine’s line of lighting solutions click here.
Bodine GTD10DIM Generator Device. Switch Bypass Device (Automatic Load Control Relay) 0-10 VDC dimmer override.
Up to 10A electronic ballast/driver rating. The GTD10DIM emergency lighting control device works in conjunction with an auxiliary generator or a central inverter system to power existing fluorescent or LED fixtures for egress lighting regardless of fixture wall switch position. The device consists of
relay switching circuitry and fusing in one compact case. The GTD10DIM bypasses the fixture wall switch, allowing the building’s generator (or central inverter) to bring on switchable fixtures.
Benefits
• Allows ON/OFF switching of generator supplied emergency lighting
• Energy cost savings benefits by eliminating constant night lighting
• LED rating – Up to 10A electronic ballast rating
• 0-10 VDC dimmer override
Specifications
UL LISTED for US and Canada
UL924 Emergency Lighting Compliant
Field Installation (Indoor and Damp)
Full Warranty
5 Years
Input Voltage
120 Through 277 VAC, 50/60 Hz
LED Lighting Load Rating
Up to 10A electronic ballast rating
Temperature Rating (Ambient)
-35 to 60 C (-30 to 140 F)
Relative Humidity Range
5 to 95%, (noncondensing)
Housing
UL accepted for use in Plenum, NEMA 1
Wire
16” 600V rated
Dimensions
4.5” x 1.675” x 1.32”
(114.3 mm x 42.5 mm x 33.5 mm)
Weight
0.43 lbs.
Application
For other items like the Bodine GTD10DIM Generator Device click here.
For more information on Bodine’s line of lighting solutions click here.
Bodine GTD20A Generator Device. Branch Circuit Emergency Lighting Transfer Switch (BCELTS) Switch Bypass Device (Automatic Load Control Relay, ALCR) First Dual Listed Emergency Lighting Control Device for UL 1008 and UL 924 Universal Input.
Benefits
Allows generator supplied emergency lighting regardless of wall
switch position
• Energy costs savings benefits by eliminating constant night lighting
• Can be used with most incandescent, fluorescent and LED lighting
• Can be used as either a branch circuit emergency lighting transfer switch
(BCELTS) or switch bypass (ALCR)
Specifications
UL Listed for US and Canada under UL 924
UL Listed for the US under UL 1008
Full Warranty
5 Years (NOT pro-rata)
Universal Input Voltage
120 Through 277 VAC, 50/60 Hz
AC Input Current
45 mA
(Sensing Circuit Only)
AC Input Power Rating
4.0 Watts
(Sensing Circuit Only)
Approved Lighting Loads
Any Type
Lighting Load Rating
20 A Maximum
Temperature Rating (Ambient)
-20°C to +55°C (-4°F to +131°F)
Dimensions
9” x 6” x 3.5” (229 mm x 152 mm x 89 mm)
Mounting 8.5” x 2.5” (216 mm x 63.5 mm)
Weight
5 lbs. (2.3 kg
For other items like the Bodine GTD20A Generator Device click here.
For more information on Bodine’s line of lighting solutions click here.
Bodine LP500 Fluorescent Emergency Ballast
Bodine LP550 Fluorescent Emergency Ballast. Low-Profile for Space-Limited Fixtures, standard and HO T5 and T8 Lamps. End-of-Lamp-Life Compatible. The LP550 low-profile emergency ballast works in conjunction with a low-profile or standard-size AC ballast to convert new or existing standard
or high-output T5 fluorescent fixtures into unobtrusive emergency lighting. The emergency ballast consists of a high-temperature nickel cadmium battery, charger and electronic circuitry in one compact case
Benefits
• Low Profile case
• Emergency mode lumen output up to 700 lumens
• End-of-Lamp-Life Compatible
Specifications
UL LISTED
Factory or Field Installation
(Indoor and Damp)
Illumination Time
90 Minutes
Initial Light Output
390 – 700 Lumens @ 25°C
Full Warranty
5 Years (NOT pro-rata)
Dual Input Voltage
120/277 VAC, 60 Hz
AC Input Current
190 mA
AC Input Power Rating
2.6 Watts
Test Switch
Single Pole
Battery
High-Temperature, Maintenance-Free
Nickel-Cadmium Battery
7- to 10-Year Life Expectancy
Battery Charging Current
165 mA
Recharge Time
24 Hours
Charging Indicator Light
LED
Temperature Rating (Ambient)
0°C to +50°C (32°F to 122°F)
Dimensions
18.5” x 1.18” x 1.18”
(470 mm x 30 mm x 30 mm)
Mounting Center 18.1” (460 mm)
Weight
2.3 lbs. (1.0 kg)
For other items like the Bodine LP550 Fluorescent Emergency Ballast click here.
For more information on Bodine’s line of lighting solutions click here.
Bodine LP600 Fluorescent Emergency Ballast. Low-Profile for Space-Limited Fixtures, standard and HO T5 and T8 Lamps. End-of-Lamp-Life Compatible. The LP600 low-profile emergency ballast works in conjunction with a low-profile or standard-size AC ballast to convert new or existing standard or
high-output T5 and T8 fluorescent fixtures into unobtrusive emergency lighting. The emergency ballast consists of a high-temperature nickelcadmium battery, charger and electronic circuitry in one compact case
Benefits
• Low Profile case
• Emergency mode lumen output up to 1325 lumens
• End-of-Lamp-Life Compatible
• Compatible with TLED lamps (see Table 1)
Specifications
UL Listed for US and Canada
Listed to UL924 and tested to CSA 22.2 No. 141
Field or Factory Installation (Indoor and Damp)Output Class 2 Compliant
Illumination Time
90 Minutes
Initial Light Output
600 – 1325 Lumens @ 25°C
Full Warranty
5 Years (NOT pro-rata)
Dual Input Voltage
120/277 VAC, 60 Hz
AC Input Current
180 mA
AC Input Power Rating
3.0 Watts
Test Switch
Single Pole
Battery
High-Temperature, Maintenance-Free
Nickel-Cadmium Battery
7- to 10-Year Life Expectancy
Battery Charging Current
165 mA
Recharge Time
24 Hours
Charging Indicator Light
LED
Temperature Rating (Ambient)
0°C to +50°C (32°F to 122°F)
Dimensions
21.5” L x 1.18” W x 1.18” H
(546 mm x 30 mm x 30 mm)
Mounting Center 21.1” (536 mm)
Weight
3.3 lbs. (1.5 kg)
For other items like the Bodine LP600 Fluorescent Emergency Ballast click here.