1

Bodine ELI-S-20 Emergency Lighting Inverter

Bodine ELI-S-20 Emergency Lighting Inverter. Sinusoidal (Sine Wave) Output 20 or 25 Watts Power Auto Select 120 or 277 VAC Code-Compliant 90-Minute Runtime.

Benefits

Sine wave output
• Fused output load connections
• Works with LED and fluorescent fixtures
• Ideal for (but not limited to) screw-base LED lamps
• Auto Select feature helps reduce wiring errors
• Compatible with AC (line voltage) driven TLED lamps
• Remote-mounting up to 250 feet maximum

Specifications

UL Listed for US and Canada
Listed to UL924 and tested to CSA 22.2 No. 141
Field or Factory Installation (Indoor and Damp)Output Class 2 Compliant

Illumination Time
90 Minutes

Maximum Load Power (including AC ballast/driver)
20 W (0°C to 50°C) UL and CSA
25 W (0°C to 45°C) UL only

Full Warranty
5 years (NOT pro-rata)

AC Input Voltage
120 or 277 VAC, 60 Hz

AC Input Current
65 mA

AC Input Power Rating
8.0 W

Output Voltage
120/277 VAC (Auto Select), 60Hz

Output Current
120 V, 165 or 210 mA 277 V, 72 or 90 mA

Transfer Time
2 to 5 seconds

Test Switch
Single Pole (Momentary)

Battery
High-Temperature, Maintenance-Free ,
Nickel-Cadmium Battery,
7- to 10-year life expectancy

Battery Charging Current
250 mA

Recharge Time
24 Hours

Charging Indicator Light
LED

Temperature Rating (Ambient)
32° F to 122° F (0° C to 50° C) for 20 W
32° F to 113° F (0° C to 45° C) for 25 W
Weight
5 lbs. (2.3 kg)

For other items like the Bodine ELI-S-20 Emergency Lighting Inverter click here.

For more information on Bodine’s line of lighting solutions click here.




Bodine ELI-S-250 Emergency Lighting Inverter

Bodine ELI-S-250 Emergency Lighting Inverter. Sinusoidal (Sine Wave) Output. 250 Watts Power Maximum. Automatic Output Voltage Select. Automatic Dimming (0 to 10V) of connected Load.

Benefits

• Automatic output voltage select
• Automatic dimming (0 to 10V) of connected load
• Removable/Replaceable electronics module
• Works with LED and fluorescent fixtures
• Ideal for (but not limited to) screw-base LED lamps
• Compatible with AC (line voltage) driven TLED lamps
• Remote-mounting up to 1,000 feet maximum

Specifications

UL Listed for US and Canada
Listed to UL924 and tested to CSA 22.2, No. 141
For Field Installation (Indoor and Damp)

Maximum Output Power
250 W into load PF +/- 0.90 (280 VA)

Maximum Connected Load Power
800 W*

Illumination Time
90 Minutes

AC Input Voltage
120 VAC, 60 Hz or 277 VAC, 60 Hz

AC Input Current, (battery charging)
1000 mA Max, 120Vac or
360 mA Max, 277Vac,

Battery: 2 ea. required
12V (nominal), 35Ah
Maintenance-Free Sealed Lead Acid Battery

Recharge Time
24 Hours
Charging Indicator Light / Test Switch
Integrated LED Test Switch

Output Voltage, Automatically Selected
120 VAC +/- 10%, or 277 VAC +/- 10%

Output Frequency
60 Hz, ± 5%

Transfer Time
2 to 5 seconds

Temperature Rating (Ambient)
68° F to 86° F (20° C to 30° C)

Dimensions
12.0″ H x 12.5″ W x 10.0″ D
(317mm x 305mm x 254mm)

Weight
Enclosure and Electronics only: 16 lbs. (7.26 Kg)
Batteries, 25 lbs. ea., Batteries total: 50 lbs. (22.6 Kg)

Warranty
5 Years (not including batteries)
3 Year Battery warranty, plus 7 years additional
pro-rating

For other items like the Bodine ELI-S-250 Emergency Lighting Inverter click here.

For more information on Bodine’s line of lighting solutions click here.




Bodine ELI-S-400 Emergency Lighting Inverter

Bodine ELI-S-400 Emergency Lighting Inverter. Emergency Lighting Inverter. Sinusoidal (Sine Wave) Output. 400 VA Power Maximum.

Benefits

• Sine wave output
• 400 VA power maximum
• Transfer Time: 50 ms

Specifications

ETL Listed
Listed to UL924
For Field Installation
Illumination Time
90 Minutes
Maximum Load Power
400VA
Full Warranty
1 year full, 4 years pro-rata
Input
• Input voltage (dual): 120 or 277VAC
• Input frequency: 60 Hz
• Synchronizing slew rate: 1 Hz per second nominal
• Input surge protection: Meets UL 924
Output
• Output voltage (dual): 120 or 277VAC, 60Hz
• Output regulation: (static) ± 5% based on a
0 – 100% resistive load
• Output distortion: Less than 3% THD linear load
• Load Power Factor: .5 lag to .5 lead
• Output frequency: Normally, Synchronized to utility,
± 2 Hz during emergency
• Overload: 150% for five seconds
• Time to transfer to inverter after a utility
power failure: 50 ms.

Charging Indicator Light/Test Switch
Integrated LED/test switch

Battery Type
Maintenance-Free Sealed Lead Calcium

Recharge Time
Less than 168 Hours (meets UL924)

Battery Protection
Automatic low-battery voltage disconnect and reverse polarity
protection. Automatic restart upon utility return
Temperature Rating
68°F to 86°F (20°C to 30°C)

Dimensions
18″W x 8″D x 15″H
Weight
98 lbs (44.4 kg)

For other items like the Bodine ELI-S-400 Emergency Lighting Inverter click here.

For more information on Bodine’s line of lighting solutions click here.




Bodine GTD Emergency Lighting Control Generator Device

Bodine GTD Emergency Lighting Control Generator Device. Emergency Lighting Control Device for generator or central inverter supplied lighting. The GTD emergency lighting control device works in conjunction with an auxiliary generator or a central inverter system to power existing fluorescent or LED fixtures for egress lighting regardless of fixture wall switch position. The device consists of relay switching circuitry and
fusing in one compact galvanized steel case. One emergency lighting control device per fixture is used to bypass the fixture wall switch, allowing the building’s generator (or central inverter) to bring on switchable fixtures.

Benefits

• Allows generator supplied emergency lighting regardless of wall switch position
• Energy cost savings benefits by elimating constant night lighting
• Can be used with fluorescent or LED lighting loads
• Suitable for indoor or damp locations

Specifications

UL Listed
UL924 Emergency Lighting Compliant
Factory or Field Installation

Full Warranty
5 Years (NOT pro-rata)

Dual Input Voltage
120/277 VAC, 60 Hz

AC Input Current
280 mA

AC Input Power Rating
1.6 Watts

Fusing
All inputs fused to 3 A Maximum

Temperature Rating (Ambient)
-20°C to +65°C (-4°F to 149°F)

Dimensions
8” x 1.18” x 1.18” (204 mm x 30 mm x 30 mm)
Mounting Center 7.60” (193 mm)
Weight
0.50 lbs. (0.23 kg)

For other items like the Bodine GTD Emergency Lighting Control Generator Device click here.

For more information on Bodine’s line of lighting solutions click here.




Bodine GTD10DIM Generator Device

Bodine GTD10DIM Generator Device. Switch Bypass Device (Automatic Load Control Relay) 0-10 VDC dimmer override.
Up to 10A electronic ballast/driver rating. The GTD10DIM emergency lighting control device works in conjunction with an auxiliary generator or a central inverter system to power existing fluorescent or LED fixtures for egress lighting regardless of fixture wall switch position. The device consists of
relay switching circuitry and fusing in one compact case. The GTD10DIM bypasses the fixture wall switch, allowing the building’s generator (or central inverter) to bring on switchable fixtures.

Benefits

• Allows ON/OFF switching of generator supplied emergency lighting
• Energy cost savings benefits by eliminating constant night lighting
• LED rating – Up to 10A electronic ballast rating
• 0-10 VDC dimmer override

Specifications

UL LISTED for US and Canada
UL924 Emergency Lighting Compliant
Field Installation (Indoor and Damp)

Full Warranty
5 Years

Input Voltage
120 Through 277 VAC, 50/60 Hz

LED Lighting Load Rating
Up to 10A electronic ballast rating

Temperature Rating (Ambient)
-35 to 60 C (-30 to 140 F)

Relative Humidity Range
5 to 95%, (noncondensing)

Housing
UL accepted for use in Plenum, NEMA 1

Wire
16” 600V rated

Dimensions
4.5” x 1.675” x 1.32”
(114.3 mm x 42.5 mm x 33.5 mm)
Weight
0.43 lbs.

Application

 

For other items like the Bodine GTD10DIM Generator Device click here.

For more information on Bodine’s line of lighting solutions click here.




Bodine GTD20A Generator Device

Bodine GTD20A Generator Device. Branch Circuit Emergency Lighting Transfer Switch (BCELTS) Switch Bypass Device (Automatic Load Control Relay, ALCR) First Dual Listed Emergency Lighting Control Device for UL 1008 and UL 924 Universal Input.

Benefits

Allows generator supplied emergency lighting regardless of wall
switch position
• Energy costs savings benefits by eliminating constant night lighting
• Can be used with most incandescent, fluorescent and LED lighting
• Can be used as either a branch circuit emergency lighting transfer switch
(BCELTS) or switch bypass (ALCR)

Specifications

UL Listed for US and Canada under UL 924
UL Listed for the US under UL 1008

Full Warranty
5 Years (NOT pro-rata)

Universal Input Voltage
120 Through 277 VAC, 50/60 Hz

AC Input Current
45 mA
(Sensing Circuit Only)

AC Input Power Rating
4.0 Watts
(Sensing Circuit Only)

Approved Lighting Loads
Any Type

Lighting Load Rating
20 A Maximum

Temperature Rating (Ambient)
-20°C to +55°C (-4°F to +131°F)

Dimensions
9” x 6” x 3.5” (229 mm x 152 mm x 89 mm)
Mounting 8.5” x 2.5” (216 mm x 63.5 mm)
Weight
5 lbs. (2.3 kg

For other items like the Bodine GTD20A Generator Device click here.

For more information on Bodine’s line of lighting solutions click here.




Bodine LP600STU Emergency Ballast

Bodine LP600STU

Bodine LP600STU Emergency Ballast provides automatic code compliant testing and is compatible with HO T5 and T8 lamps. Low Profile for Space Limited Fixtures. 1300 Initial Lumen Output.

UL LISTED for US and Canada
Factory or Field Installation
(Indoor and Damp)

Illumination Time
90 Minutes

Initial Light Output
600 – 1325 Lumens @ 25°C

Full Warranty
5 Years (NOT pro-rata)

Universal Input Voltage
120 Through 277 VAC, 50 or 60 Hz

AC Input Current
55 mA

AC Input Power Rating
5.0 Watts

Test Switch / Charging Indicator Light
Two-Wire Illuminated Test Switch (2W-ITS)*
* The 2W-ITS is a Class 2 device.

Battery
High-Temperature, Maintenance-Free
Nickel-Cadmium Battery
7- to 10-Year Life Expectancy

Battery Charging Current
150 mA

Recharge Time
24 Hours

Charging Indicator Light
LED

Temperature Rating (Ambient)
0°C to +50°C (32°F to 122°F)

Dimensions
21.5” x 1.18” x 1.18”
(546.1 mm x 30 mm x 30 mm)
Mounting Center 22.1” (561 mm)

Weight
3.3 lbs. (1.5 kg)

Model LP600STU is warranted for five (5) full years from date of purchase. Please see detailed warranty information on the Signify official website.

For other items like the Bodine LP600STU Emergency Ballast click here.

For more information on Bodine’s line of lighting solutions click here.