1

SC-4PS-XX – DIVA GENERAL PURPOSE 4-WAY 15A SWITCH

DIVA GENERAL PURPOSE 4-WAY 15A SWITCH
  • 120/277V
  • Paddle turns on/off
  • Use with any 15A load
  • General purpose switching of all sources and motor loads
  • No derating if ganged



SC-4PSNL-XX – DIVA GENERAL PURPOSE 4-WAY 15A SWITCH W/ LOCATOR LIGHT

DIVA GENERAL PURPOSE 4-WAY 15A SWITCH W/ LOCATOR LIGHT
  • 120V ONLY
  • Paddle turns on/off
  • Use with any 15A load
  • General purpose switching of all sources and motor loads
  • No derating if ganged



SC-5-XX – SATIN WALLPLATE 5-GANG

SATIN WALLPLATE 5-GANG, LIGHTING CONTROLS

This is the Satin Wallplate 5-Gang. Check out the RadioRA 2 products page here.

  • Can be used in conjunction with the following dimmer(s) and switch(es): Maestro®, Maestro IR®, Maestro Wireless®, Pico™ wireless control, Spacer System®, Diva®, Lyneo® Lx, Skylark®, Skylark Contour™
  • All Lutron® wallplates are screwless, seamless and have no visible hardware; the front plate securely snaps into the alignment adapter plate
  • Full line of wiring devices in designer style opening
  • Blank inserts available for Gloss colors and Satin colors
  • Customize your designer wallplate with engraving



SC-6-XX – SATIN COLORS 6-GANG WALLPLATE

SATIN COLORS 6-GANG WALLPLATE
  • Multi-gang dimmer installations may require derating
  • Stainless Steel finish wallplates include black plastic trim/adapter, visible from side. Match with separate Black (BL) or Midnight (MN) controls and accessories



SCR-15-GFST-XX – TAMPER RESISTANT, SELF-TESTING 15A GFCI RECEPTACLES

TAMPER RESISTANT, SELF-TESTING 15A GFCI RECEPTACLES
  • Continuous self-test functionality
  • Three provisions for providing protection:
    • Continuous electronic sensing, testing and evaluation utilizing diagnostic software located on the printed circuit board.
    • Traditional testing mode by manually operating the “test and reset” buttons utilizing a supervisory circuit as specified in UL 943 section 5.15.
    • Auto-sensing mode for immediate interruption for a ground fault condition for Class A protection (4 – 6 mA).
  • Manual Test – this design incorporates a full system test function
  • Reverse wire safety feature



SCR-15-HDTR-XX – TAMPER RESISTANT 15A RECEPTACLE FOR DIMMING USE

TAMPER RESISTANT 15A RECEPTACLE FOR DIMMING USE

RECEPTACLES FOR DIMMING USE

  • Top half for dimming
  • Projecting nub prevents standard plug from being used
  • Requires replacement plugs for dimming use
  • Bottom half is a general use receptacle and will fit standard duplex plugs
  • Tamper resistant shutter mechanism



SCR-15-UBTR-XX – USB RECEPTACLE – 15 A

USB RECEPTACLE - 15 A
  • Dual USB ports.
  • Color and texture matches Lutron dimmers.
  • Wallplates available in a variety of colors and finishes.
  • Tamper resistant.
  • Side or back wire installation capable.



SCR-15-XX -LUTRON 15A RECEPTACLE

LUTRON 15A RECEPTACLE
  • Reverse wire safety feature – if wired incorrectly there will be no power to the face or to downstream receptacles for added safety.
  • Internal back wiring clamp and guide pocket — quick and dependable termination.
  • Receptacle face compatible with NEMA designer and NovaT*® designer-opening wallplates.



SCR-20-DDTR-XX – LUTRON 20A TAMPER RESISTANT RECEPTACLE FOR DIMMING USE

LUTRON 20A TAMPER RESISTANT RECEPTACLE FOR DIMMING USE

Tamper resistant receptacles, unlike traditional receptacles, offer the added protection of a permanently installed, spring-loaded slider mechanism capable of resisting insertion of single pronged elements (such as keys, hairpins, or nails) while still allowing access to electrical plugs. Lutron Tamper Resistant Receptacles are compliant with article 406.11 of the 2008 National Electric Code (NEC®). The NEC prohibits the dimming of standard receptacles. The dimmable outlets of the Dual Dimming Tamper Resistant (DDTR) and Half Dimming Tamper Resistant (HDTR) are specifically designed to mechanicaly reject all NEMA standard plugs and thus can not be used for any other device (fan, heater, vacuum, radio, etc.). These receptacles will only accept the special mating Lutron replacement plug for dimming use (RP-FDU). The result is an NEC compliant way to control a portable lamp with a dimmer.




SCR-20-GFST-XX – TAMPER RESISTANT, SELF-TESTING 20A GFCI RECEPTACLES

TAMPER RESISTANT, SELF-TESTING 20A GFCI RECEPTACLES
  • Continuous self-test functionality – disconnects power to receptacle if critical components are damaged and GFCI protection is lost – providing “continuous self-testing” that initiates within 2.5 seconds and is a continuous cycle every 30 seconds or less.
  • Three provisions for providing protection: – Continuous electronic sensing, testing and evaluation utilizing diagnostic software located on the printed circuit board. – Traditional testing mode by manually operating the “test and reset” buttons utilizing a supervisory circuit as specified in UL 943 section 5.15. – Auto-sensing mode for immediate interruption for a ground fault condition for Class A protection (4 – 6 mA).
  • Manual Test – this design incorporates a full system test function. The GFCI, when manually tested, induces a simulated ground fault leakage current to the printed circuit board. This in turn causes the mechanical system to react based on the action of the solenoid. The entire mechanical and electronic GFCI system is reviewed for functionality.
  • Reverse wire safety feature – if wired incorrectly there will be no power to the face or to downstream receptacles for added safety.
  • Clear visual indication of GFCI status — LED indicating lights: – Green LED (power to the device) – Red LED (trip condition/ground fault condition) – Flashing Red LED (end of life)
  • Permanently installed internal tamper-resistant shutter mechanism capable of resisting insertion of foreign elements into the device.
  • Internal back wiring clamp and guide pocket — quick and dependable termination.
  • Receptacle face compatible with NEMA designer and NovaT*® designer-opening wallplates.
  • Compliant with NEC® 406.12 and NEC® 517-18(c)



SCR-20-HDTR-XX – LUTRON 20A TAMPER RESISTANT RECEPTACLE FOR DIMMING USE

LUTRON 20A TAMPER RESISTANT RECEPTACLE FOR DIMMING USE

Tamper resistant receptacles, unlike traditional receptacles, offer the added protection of a permanently installed, spring-loaded slider mechanism capable of resisting insertion of single pronged elements (such as keys, hairpins, or nails) while still allowing access to electrical plugs. Lutron Tamper Resistant Receptacles are compliant with article 406.11 of the 2008 National Electric Code (NEC®). The NEC prohibits the dimming of standard receptacles. The dimmable outlets of the Dual Dimming Tamper Resistant (DDTR) and Half Dimming Tamper Resistant (HDTR) are specifically designed to mechanicaly reject all NEMA standard plugs and thus can not be used for any other device (fan, heater, vacuum, radio, etc.). These receptacles will only accept the special mating Lutron replacement plug for dimming use (RP-FDU). The result is an NEC compliant way to control a portable lamp with a dimmer.




SCR-20-XX – LUTRON 20A RECEPTACLE

LUTRON 20A RECEPTACLE
  • Reverse wire safety feature – if wired incorrectly there will be no power to the face or to downstream receptacles for added safety.
  • Internal back wiring clamp and guide pocket — quick and dependable termination.
  • Receptacle face compatible with NEMA designer and NovaT*® designer-opening wallplates.