1

GRX-CBL-46L-500 – 500 ft GRAFIK 4000/6000 CTRL CABLE

500 ft GRAFIK 4000/6000 CTRL CABLE
  • Non-Plenum rated cable for use with the following Lutron systems
    • GRAFIK Eye ® 3000
    • GRAFIK Eye ® QS
    • Energi Savr Node TM



GRX-IT-WH – 4-Scene Wireless Remote Control Infrared Transmitter

4-Scene Wireless Remote Control Infrared Transmitter
  • Uses wireless infrared communications to select and adjust scenes.
  • Scene selection buttons select four scenes.
  • Off button turns all lights off.
  • Master raise/lower button brightens or dims all lighting zones.
  • Works with GRAFIK Eye 3000 and 4000 Series Control Units or any Wallstation with an infrared receiver.



GRX-TVI – Ten Volt Interface

Ten Volt Interface
  • 100-277 V~ forward, reverse, and center phase control input capability
  • Provides 0—10 V- control and switching capabilities to switch and dim current sourcing fluorescent ballasts and LED drivers.
  • Switches and dims current sourcing 0—10 VDC electronic dimming ballasts/drivers powered by
    100—277 VAC. Switches up to 16 A of electronic capacitive ballasts/drivers.



L-CMDPIRKIT – TEN (10) TEMPORARY MOUNTING STRIPS

TEN (10) TEMPORARY MOUNTING STRIPS

Solid Ceiling (Drywall, Plaster, Concrete, or Wood)

  • Temporary mounting: Ten (10) temporary mounting strips can be purchased in the kit, L-CMDPIRKIT, for temporarily mounting and testing the sensor.
  • Permanent mounting: Screws and anchors (for drywall or plaster) provided to mount the sensor.



L-CRMK-WH – RECESS-MOUNTING RING

RECESS-MOUNTING RING

Recess-Mount:

  • Do not recess-mount sensor in a metal surface.
  • Recess-mounting ring requires an opening of 3 in (76 mm) in diameter.
  • Recess-mounting ring secures internally to ceiling. Sensor twists into the recess mounting ring and sits flush with ceiling.



L-HWLV2-WIFI – HONEYWELL VISONPRO WI-FI THERMOSTAT

HONEYWELL VISONPRO WI-FI THERMOSTAT
  • Adjust temperature settings anytime from the Lutron app – whether home or away.
  • 7-day programmable schedule.
  • Large touchscreen display with backlight.
  • Communicates via Wi-Fi technology.
  • Smart Response Technology – continually learns when to pre-heat/cool your home so you are comfortable at your pre-programmed times.
  • Supports up to 3 heat and 2 cool stages.



L-PEDX-XX – TABLTOP PEDESTAL (1-3 PEDESTAL OPTIONS)

TABLTOP PEDESTAL (1-4 PEDESTAL OPTIONS)
  • Mount the Pico to a pedestal and you have a simple and elegant tabletop control.
  • Single, double, and triple pedestals available. Please note that Lutron has discontinued production of the 4-Pedestal option.
  • White and black options available



LMLS MB – PHOTOSENSOR MOUNTING BRACKET

PHOTOSENSOR MOUNTING BRACKET

The LMLS-MB1 and LMLS-MB2 mounting brackets provide the flexibility to mount the LMLS-400 and LMLS-500 Photosensors to walls, skylight wells or J-Boxes. They are specifically designed to be used in conjunction with these Photosensors.

FEATURES:

  • Material: ABS, UL 94 5V Flame Retardant Material
  • Indoor Use Only
  • Mounting Options:
  • LMLS-MB1: 4-Square J-Box / 2-Gang J-Box
  • LMLS-MB2: Screw to Wall / Tape to wall with double sided tape



LRM-2P-120/347 – LOCAL RELAY MODULE W/ OPTIONAL, 2-CHANNEL, 0-10V DIMMING

LOCAL RELAY MODULE W/ OPTIONAL, 2-CHANNEL, 0-10V DIMMING, LIGHTING CONTROLS

This is the Local Relay Module w/ optional, 2-channel, 0-10V Dimming.

  • Provide a distributed control solution which allows the installer to place the module in close proximity to the controlled load.
  • Can be connected directly to a master interface or through multi-function interfaces.
  • Local Relay Modules each encompass (2) latching (mechanically held) single pole relays and each module incorporates the latest in “zero-cross” switching technology for improved equipment life.
  • Include (3) “smart ports.” Each smart port provides a daisy-chained connection for up to (8) smart devices and are connected to the Local Relay Modules via standard Cat5 patch cables.



PHPM-PA-120-WH – PHASE-ADAPTIVE POWER MODULE

PHASE-ADAPTIVE POWER MODULE
  • Provides capability for a zone on a GRAFIK Eye control unit (or other product) to dim a fully loaded circuit of lighting.
  • May be used to control incandescent, electronic low-voltage, magnetic low-voltage, and neon/cold cathode lighting sources, as well as Lutron Tu-Wire fluorescent dimming ballasts.
  • Automatically selects leading-edge or trailing-edge dimming for low-voltage transformers.
  • Provides power and dimming for one zone.
  • Up to 3 power modules may be wired on a single GRAFIK Eye zone.



PHPM-PA-DV-WH – DUAL VOLTAGE PHASE-ADAPTIVE POWER MODULE

DUAL VOLTAGE PHASE-ADAPTIVE POWER MODULE
  • Provides capability for a zone on a GRAFIK Eye control unit (or other product) to dim a fully loaded circuit of lighting.
  • May be used to control incandescent, electronic low-voltage, magnetic low-voltage, and neon/cold cathode lighting sources, as well as Lutron Tu-Wire fluorescent dimming ballasts.
  • Automatically selects leading-edge or trailing-edge dimming for low-voltage transformers.
  • Provides power and dimming for one zone.
  • Up to 3 power modules may be wired on a single GRAFIK Eye zone.



PICO-SM-KIT – SCREW-MOUNT KIT FOR PICO® WIRELESS CONTROL

SCREW-MOUNT KIT FOR PICO® WIRELESS CONTROL

Mounting Considerations:

  • Mounting of any RF devices on or in close proximity to a metal surface will drastically reduce the effective range of radio signal transmission or reception.
  • All RF devices must be mounted on non-conductive materials to ensure proper performance.
  • If you wish to mount your PicoR wireless control to a metal surface, the PICO-MOUNT-1-XX-CPN5733 will be required in order to maintain proper RF performance.