1

SCR-20-DDTR-XX – LUTRON 20A TAMPER RESISTANT RECEPTACLE FOR DIMMING USE

LUTRON 20A TAMPER RESISTANT RECEPTACLE FOR DIMMING USE

Tamper resistant receptacles, unlike traditional receptacles, offer the added protection of a permanently installed, spring-loaded slider mechanism capable of resisting insertion of single pronged elements (such as keys, hairpins, or nails) while still allowing access to electrical plugs. Lutron Tamper Resistant Receptacles are compliant with article 406.11 of the 2008 National Electric Code (NEC®). The NEC prohibits the dimming of standard receptacles. The dimmable outlets of the Dual Dimming Tamper Resistant (DDTR) and Half Dimming Tamper Resistant (HDTR) are specifically designed to mechanicaly reject all NEMA standard plugs and thus can not be used for any other device (fan, heater, vacuum, radio, etc.). These receptacles will only accept the special mating Lutron replacement plug for dimming use (RP-FDU). The result is an NEC compliant way to control a portable lamp with a dimmer.




SCR-20-GFST-XX – TAMPER RESISTANT, SELF-TESTING 20A GFCI RECEPTACLES

TAMPER RESISTANT, SELF-TESTING 20A GFCI RECEPTACLES
  • Continuous self-test functionality – disconnects power to receptacle if critical components are damaged and GFCI protection is lost – providing “continuous self-testing” that initiates within 2.5 seconds and is a continuous cycle every 30 seconds or less.
  • Three provisions for providing protection: – Continuous electronic sensing, testing and evaluation utilizing diagnostic software located on the printed circuit board. – Traditional testing mode by manually operating the “test and reset” buttons utilizing a supervisory circuit as specified in UL 943 section 5.15. – Auto-sensing mode for immediate interruption for a ground fault condition for Class A protection (4 – 6 mA).
  • Manual Test – this design incorporates a full system test function. The GFCI, when manually tested, induces a simulated ground fault leakage current to the printed circuit board. This in turn causes the mechanical system to react based on the action of the solenoid. The entire mechanical and electronic GFCI system is reviewed for functionality.
  • Reverse wire safety feature – if wired incorrectly there will be no power to the face or to downstream receptacles for added safety.
  • Clear visual indication of GFCI status — LED indicating lights: – Green LED (power to the device) – Red LED (trip condition/ground fault condition) – Flashing Red LED (end of life)
  • Permanently installed internal tamper-resistant shutter mechanism capable of resisting insertion of foreign elements into the device.
  • Internal back wiring clamp and guide pocket — quick and dependable termination.
  • Receptacle face compatible with NEMA designer and NovaT*® designer-opening wallplates.
  • Compliant with NEC® 406.12 and NEC® 517-18(c)



SCR-20-HDTR-XX – LUTRON 20A TAMPER RESISTANT RECEPTACLE FOR DIMMING USE

LUTRON 20A TAMPER RESISTANT RECEPTACLE FOR DIMMING USE

Tamper resistant receptacles, unlike traditional receptacles, offer the added protection of a permanently installed, spring-loaded slider mechanism capable of resisting insertion of single pronged elements (such as keys, hairpins, or nails) while still allowing access to electrical plugs. Lutron Tamper Resistant Receptacles are compliant with article 406.11 of the 2008 National Electric Code (NEC®). The NEC prohibits the dimming of standard receptacles. The dimmable outlets of the Dual Dimming Tamper Resistant (DDTR) and Half Dimming Tamper Resistant (HDTR) are specifically designed to mechanicaly reject all NEMA standard plugs and thus can not be used for any other device (fan, heater, vacuum, radio, etc.). These receptacles will only accept the special mating Lutron replacement plug for dimming use (RP-FDU). The result is an NEC compliant way to control a portable lamp with a dimmer.




SCR-20-XX – LUTRON 20A RECEPTACLE

LUTRON 20A RECEPTACLE
  • Reverse wire safety feature – if wired incorrectly there will be no power to the face or to downstream receptacles for added safety.
  • Internal back wiring clamp and guide pocket — quick and dependable termination.
  • Receptacle face compatible with NEMA designer and NovaT*® designer-opening wallplates.



SCRS-20-TR- 20 AMP TAMPER RESISTANT GFCI RECEPTACLE

LUTRON 20A TAMPER RESISTANT RECEPTACLE, HOME AUTOMATION, COMMERCIAL BUILDING CONTROLS, CHILDPROOFING, GFCI

20 Amp Tamper Resistant GFCI Receptacle

Features

  • Continuous self-test functionality – disconnects power to receptacle if critical components are damaged and GFCI protection is lost – providing “continuous self-testing” that initiates within 2.5 seconds and is a continuous cycle every 30 seconds or less.
  • There are three provisions for providing protection with this 20 Amp Tamper Resistant GFCI Receptacle:

– Continuous electronic sensing, testing and evaluation utilizing diagnostic software located on the printed circuit board.

– Traditional testing mode by manually operating the “test and reset” buttons utilizing a supervisory circuit as specified in UL 943 section 5.15.

– Auto-sensing mode for immediate interruption for a ground fault condition for Class A protection (4 – 6 mA).

  • Manual Test – this design incorporates a full system test function. The GFCI, when manually tested, induces a simulated ground fault leakage current to the printed circuit board. This in turn causes the mechanical system to react based on the action of the solenoid. The entire mechanical and electronic GFCI system is reviewed for functionality.
  • Reverse wire safety feature – if wired incorrectly there will be no power to the face or to downstream receptacles for added safety.
  • Clear visual indication of GFCI status — LED indicating lights:

– Green LED (power to the device)

– Red LED (trip condition/ground fault condition)

– Flashing Red LED (end of life)

  • Permanently installed internal tamper-resistant shutter mechanism capable of resisting insertion of foreign elements into the device.
  • Internal back wiring clamp and guide pocket — quick and dependable termination.
  • Receptacle face compatible with NEMA designer and NovaT designer-opening wallplates.
  • Compliant with NEC 406.12 and NEC 517-18(c).